GUDEADS-ENC2302-MIB DEFINITIONS ::= BEGIN

IMPORTS
	enterprises,
	MODULE-IDENTITY,
	OBJECT-TYPE,
	NOTIFICATION-TYPE,
	Integer32,
	Unsigned32
		FROM SNMPv2-SMI
	OBJECT-GROUP,
	NOTIFICATION-GROUP
		FROM SNMPv2-CONF;

gudeads MODULE-IDENTITY
	LAST-UPDATED "202505260805Z"	-- May 26, 2025, 8:05:00 AM
	ORGANIZATION "GUDE Systems GmbH"
	CONTACT-INFO
		"Von-der-Wettern-Str. 23
		51149 Cologne
		Germany
		https://www.gude-sytems.com"
	DESCRIPTION
		"Expert Net Control 2302 MIB"
	-- 1.3.6.1.4.1.28507
	::= { enterprises 28507 }


enc2302InputToggleCount OBJECT-TYPE
	SYNTAX  Unsigned32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Number of times the Input has changed its state."
	-- 1.3.6.1.4.1.28507.70.1.5.6.2.1.3
	::= { enc2302InputEntry 3 }


enc2302ExtInputToggleCount OBJECT-TYPE
	SYNTAX  Unsigned32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Number of times the Input has changed its state."
	-- 1.3.6.1.4.1.28507.70.1.6.2.2.1.3
	::= { enc2302ExtInputEntry 3 }


enc2302ExtInputs OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.6.2
	::= { enc2302ExtSensors 2 }

enc2302ExtInputEntry OBJECT-TYPE
	SYNTAX  Enc2302ExtInputEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION ""
	INDEX {
		enc2302ExtInputIndex }
	-- 1.3.6.1.4.1.28507.70.1.6.2.2.1
	::= { enc2302ExtInputTable 1 }


Enc2302ExtInputEntry ::= SEQUENCE {

	enc2302ExtInputIndex       Unsigned32,
	enc2302ExtInput            INTEGER,
	enc2302ExtInputToggleCount Unsigned32,
	enc2302ExtInputName        OCTET STRING,
	enc2302ExtInputPortNum     Integer32,
	enc2302ExtInputBlockIndex  Integer32 }


enc2302ExtInput OBJECT-TYPE
	SYNTAX  INTEGER {
			lo(0),
			hi(1) }
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Input state of device"
	-- 1.3.6.1.4.1.28507.70.1.6.2.2.1.2
	::= { enc2302ExtInputEntry 2 }


enc2302ExtActiveInputs OBJECT-TYPE
	SYNTAX  Unsigned32 (1..12)
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Number of suppported Input Channels."
	-- 1.3.6.1.4.1.28507.70.1.6.2.1
	::= { enc2302ExtInputs 1 }


enc2302ExtInputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Enc2302ExtInputEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION ""
	-- 1.3.6.1.4.1.28507.70.1.6.2.2
	::= { enc2302ExtInputs 2 }


enc2302ExtInputIndex OBJECT-TYPE
	SYNTAX  Unsigned32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION ""
	-- 1.3.6.1.4.1.28507.70.1.6.2.2.1.1
	::= { enc2302ExtInputEntry 1 }


enc2302ExtInputName OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (0..32))
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"A textual string containing name of
		the Input"
	-- 1.3.6.1.4.1.28507.70.1.6.2.2.1.32
	::= { enc2302ExtInputEntry 32 }


enc2302ExtInputPortNum OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Number of external Sensor Port when value greater zero, else device built-in Input."
	-- 1.3.6.1.4.1.28507.70.1.6.2.2.1.33
	::= { enc2302ExtInputEntry 33 }


enc2302ExtInputBlockIndex OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Either index of device built-in Input, or index of Input in external sensor."
	-- 1.3.6.1.4.1.28507.70.1.6.2.2.1.34
	::= { enc2302ExtInputEntry 34 }


enc2302NTPClient OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.5.15
	::= { enc2302IntSensors 15 }

enc2302NTPUnixTime OBJECT-TYPE
	SYNTAX  Unsigned32
	UNITS	"s"
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"show received NTP time as unixtime (secs since 1 January 1970)"
	-- 1.3.6.1.4.1.28507.70.1.5.15.2
	::= { enc2302NTPClient 2 }


enc2302NTPLastValidTimestamp OBJECT-TYPE
	SYNTAX  Unsigned32
	UNITS	"s"
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"show seconds since last valid NTP timestamp received"
	-- 1.3.6.1.4.1.28507.70.1.5.15.3
	::= { enc2302NTPClient 3 }


enc2302NTPTimeValid OBJECT-TYPE
	SYNTAX  INTEGER {
			notime(0),
			valid(1) }
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Show if valid Time is received"
	-- 1.3.6.1.4.1.28507.70.1.5.15.1
	::= { enc2302NTPClient 1 }


enc2302PortResetDuration OBJECT-TYPE
	SYNTAX  Integer32 (0..65535)
	UNITS	"seconds"
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"Delay in sec for turning Port on again after Reset action"
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1.8
	::= { enc2302portEntry 8 }


enc2302InputName OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (0..32))
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"A textual string containing name of
		the Input"
	-- 1.3.6.1.4.1.28507.70.1.5.6.2.1.32
	::= { enc2302InputEntry 32 }


enc2302ExtSensorName OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (0..32))
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"A textual string containing name of a
		external Sensor"
	-- 1.3.6.1.4.1.28507.70.1.6.1.1.32
	::= { enc2302SensorEntry 32 }


enc2302SensorTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Enc2302SensorEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION ""
	-- 1.3.6.1.4.1.28507.70.1.6.1
	::= { enc2302ExtSensors 1 }


enc2302SensorEntry OBJECT-TYPE
	SYNTAX  Enc2302SensorEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION ""
	INDEX {
		enc2302SensorIndex }
	-- 1.3.6.1.4.1.28507.70.1.6.1.1
	::= { enc2302SensorTable 1 }


Enc2302SensorEntry ::= SEQUENCE {

	enc2302SensorIndex   Integer32,
	enc2302TempSensor    Integer32,
	enc2302HygroSensor   Integer32,
	enc2302InputSensor   INTEGER,
	enc2302AirPressure   Integer32,
	enc2302DewPoint      Integer32,
	enc2302DewPointDiff  Integer32,
	enc2302ExtSensorName OCTET STRING }


enc2302SensorIndex OBJECT-TYPE
	SYNTAX  Integer32 (1..4)
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION ""
	-- 1.3.6.1.4.1.28507.70.1.6.1.1.1
	::= { enc2302SensorEntry 1 }


enc2302TempSensor OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"actual temperature"
	-- 1.3.6.1.4.1.28507.70.1.6.1.1.2
	::= { enc2302SensorEntry 2 }


enc2302HygroSensor OBJECT-TYPE
	SYNTAX  Integer32
	UNITS	"0.1 percent humidity"
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"actual humidity"
	-- 1.3.6.1.4.1.28507.70.1.6.1.1.3
	::= { enc2302SensorEntry 3 }


enc2302InputSensor OBJECT-TYPE
	SYNTAX  INTEGER {
			off(0),
			on(1) }
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"logical state of input sensor"
	-- 1.3.6.1.4.1.28507.70.1.6.1.1.4
	::= { enc2302SensorEntry 4 }


enc2302AirPressure OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"actual air pressure"
	-- 1.3.6.1.4.1.28507.70.1.6.1.1.5
	::= { enc2302SensorEntry 5 }


enc2302DewPoint OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"dew point for actual temperature and humidity"
	-- 1.3.6.1.4.1.28507.70.1.6.1.1.6
	::= { enc2302SensorEntry 6 }


enc2302DewPointDiff OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"difference between dew point and actual
		temperature (Temp - DewPoint)"
	-- 1.3.6.1.4.1.28507.70.1.6.1.1.7
	::= { enc2302SensorEntry 7 }


gadsENC2302 OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70
	::= { gudeads 70 }

-- Scalars and Tables
--

enc2302Objects OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1
	::= { gadsENC2302 1 }

enc2302CommonConfig OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.1
	::= { enc2302Objects 1 }

enc2302SNMPaccess OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.1.1
	::= { enc2302CommonConfig 1 }

enc2302TrapCtrl OBJECT-TYPE
	SYNTAX  Integer32 (0..3)
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"0 = off
		1 = Ver. 1
		2 = Ver. 2c
		3 = Ver. 3"
	-- 1.3.6.1.4.1.28507.70.1.1.1.1
	::= { enc2302SNMPaccess 1 }


enc2302TrapIPTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Enc2302TrapIPEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION
		"list of all Trap receiver"
	-- 1.3.6.1.4.1.28507.70.1.1.1.2
	::= { enc2302SNMPaccess 2 }


enc2302TrapIPEntry OBJECT-TYPE
	SYNTAX  Enc2302TrapIPEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION
		"an entry containing management
		informations regarding the list of trap
		receivers"
	INDEX {
		enc2302TrapIPIndex }
	-- 1.3.6.1.4.1.28507.70.1.1.1.2.1
	::= { enc2302TrapIPTable 1 }


Enc2302TrapIPEntry ::= SEQUENCE {

	enc2302TrapIPIndex Integer32,
	enc2302TrapAddr    OCTET STRING }


enc2302TrapIPIndex OBJECT-TYPE
	SYNTAX  Integer32 (1..8)
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"A unique value, greater than zero, for each receiver slot."
	-- 1.3.6.1.4.1.28507.70.1.1.1.2.1.1
	::= { enc2302TrapIPEntry 1 }


enc2302TrapAddr OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (0..99))
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"DNS name or IP address specifying one Trap receiver slot.
		A port can optionally be specified: 'name:port' An empty
		string disables this slot."
	-- 1.3.6.1.4.1.28507.70.1.1.1.2.1.2
	::= { enc2302TrapIPEntry 2 }


enc2302DeviceConfig OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.2
	::= { enc2302Objects 2 }

enc2302IntActors OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.3
	::= { enc2302Objects 3 }

enc2302relayports OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.3.1
	::= { enc2302IntActors 1 }

enc2302portNumber OBJECT-TYPE
	SYNTAX  Integer32 (1..4)
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"The number of Relay Ports"
	-- 1.3.6.1.4.1.28507.70.1.3.1.1
	::= { enc2302relayports 1 }


-- the Interfaces table
-- The Interfaces table contains information on the entity's
-- interfaces.  Each sub-layer below the internetwork-layer
-- of a network interface is considered to be an interface.

enc2302portTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Enc2302portEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION
		"list of all ENC Relay Ports"
	-- 1.3.6.1.4.1.28507.70.1.3.1.2
	::= { enc2302relayports 2 }


enc2302portEntry OBJECT-TYPE
	SYNTAX  Enc2302portEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION
		"An entry containing management information applicable to a
		particular relay port."
	INDEX {
		enc2302PortIndex }
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1
	::= { enc2302portTable 1 }


Enc2302portEntry ::= SEQUENCE {

	enc2302PortIndex         Integer32,
	enc2302PortName          OCTET STRING,
	enc2302PortState         INTEGER,
	enc2302PortSwitchCount   Integer32,
	enc2302PortStartupMode   INTEGER,
	enc2302PortStartupDelay  Integer32,
	enc2302PortRepowerTime   Integer32,
	enc2302PortResetDuration Integer32 }


enc2302PortIndex OBJECT-TYPE
	SYNTAX  Integer32 (1..4)
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"A unique value, greater than zero, for each Relay Port."
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1.1
	::= { enc2302portEntry 1 }


enc2302PortName OBJECT-TYPE
	SYNTAX  OCTET STRING (SIZE (0..15))
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"A textual string containing name of a Relay Port."
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1.2
	::= { enc2302portEntry 2 }


enc2302PortState OBJECT-TYPE
	SYNTAX  INTEGER {
			off(0),
			on(1) }
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"current state a Relay Port"
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1.3
	::= { enc2302portEntry 3 }


enc2302PortSwitchCount OBJECT-TYPE
	SYNTAX  Integer32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"The total number of switch actions ocurred on a Relay Port.
		Does not count switch commands which will not switch
		the ralay state, so just real relay switches are displayed here."
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1.4
	::= { enc2302portEntry 4 }


enc2302PortStartupMode OBJECT-TYPE
	SYNTAX  INTEGER {
			off(0),
			on(1),
			laststate(2) }
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"set Mode of startup sequence (off, on , remember last state)"
	DEFVAL { off }
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1.5
	::= { enc2302portEntry 5 }


enc2302PortStartupDelay OBJECT-TYPE
	SYNTAX  Integer32
	UNITS	"seconds"
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"Delay in sec for startup action"
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1.6
	::= { enc2302portEntry 6 }


enc2302PortRepowerTime OBJECT-TYPE
	SYNTAX  Integer32 (0..65535)
	UNITS	"seconds"
	MAX-ACCESS read-write
	STATUS  current
	DESCRIPTION
		"Delay in sec for repower port after switching off"
	DEFVAL { 0 }
	-- 1.3.6.1.4.1.28507.70.1.3.1.2.1.7
	::= { enc2302portEntry 7 }


enc2302ExtActors OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.4
	::= { enc2302Objects 4 }

enc2302IntSensors OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.5
	::= { enc2302Objects 5 }

enc2302ExtSensors OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.6
	::= { enc2302Objects 6 }

enc2302Inputs OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.5.6
	::= { enc2302IntSensors 6 }

enc2302ActiveInputs OBJECT-TYPE
	SYNTAX  Unsigned32 (1)
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Number of suppported Input Channels."
	-- 1.3.6.1.4.1.28507.70.1.5.6.1
	::= { enc2302Inputs 1 }


enc2302InputTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF Enc2302InputEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION ""
	-- 1.3.6.1.4.1.28507.70.1.5.6.2
	::= { enc2302Inputs 2 }


enc2302InputEntry OBJECT-TYPE
	SYNTAX  Enc2302InputEntry
	MAX-ACCESS not-accessible
	STATUS  current
	DESCRIPTION ""
	INDEX {
		enc2302InputIndex }
	-- 1.3.6.1.4.1.28507.70.1.5.6.2.1
	::= { enc2302InputTable 1 }


Enc2302InputEntry ::= SEQUENCE {

	enc2302InputIndex       Integer32,
	enc2302Input            INTEGER,
	enc2302InputToggleCount Unsigned32,
	enc2302InputName        OCTET STRING }


enc2302InputIndex OBJECT-TYPE
	SYNTAX  Integer32 (1..8)
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION ""
	-- 1.3.6.1.4.1.28507.70.1.5.6.2.1.1
	::= { enc2302InputEntry 1 }


enc2302Input OBJECT-TYPE
	SYNTAX  INTEGER {
			lo(0),
			hi(1) }
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Input state of device"
	-- 1.3.6.1.4.1.28507.70.1.5.6.2.1.2
	::= { enc2302InputEntry 2 }


-- Conformance
--

enc2302Conf OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.2
	::= { gadsENC2302 2 }

-- Groups
--

enc2302Groups OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.2.1
	::= { enc2302Conf 1 }

-- Compliance
--

enc2302Compls OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.2.2
	::= { enc2302Conf 2 }

enc2302BasicGroup OBJECT-GROUP
	OBJECTS {
		enc2302TrapCtrl,
		enc2302TrapIPIndex,
		enc2302TrapAddr,
		enc2302portNumber,
		enc2302PortIndex,
		enc2302PortName,
		enc2302PortState,
		enc2302PortSwitchCount,
		enc2302PortStartupMode,
		enc2302PortStartupDelay,
		enc2302PortRepowerTime,
		enc2302ActiveInputs,
		enc2302InputIndex,
		enc2302Input,
		enc2302SensorIndex,
		enc2302TempSensor,
		enc2302HygroSensor,
		enc2302InputSensor,
		enc2302AirPressure,
		enc2302DewPoint,
		enc2302DewPointDiff,
		enc2302StopPressed,
		enc2302ExtSensorName,
		enc2302InputName,
		enc2302PortResetDuration,
		enc2302NTPTimeValid,
		enc2302NTPUnixTime,
		enc2302NTPLastValidTimestamp,
		enc2302ExtActiveInputs,
		enc2302ExtInputIndex,
		enc2302ExtInput,
		enc2302ExtInputName,
		enc2302ExtInputPortNum,
		enc2302ExtInputBlockIndex,
		enc2302InputToggleCount,
		enc2302ExtInputToggleCount,
		enc2302ProdName,
		enc2302FWVersion,
		enc2302HostName,
		enc2302PhysAddress,
		enc2302SerialNumber }
	STATUS  current
	DESCRIPTION
		"Basic objects."
	-- 1.3.6.1.4.1.28507.70.2.1.1
	::= { enc2302Groups 1 }

enc2302NotificationGroup NOTIFICATION-GROUP
	NOTIFICATIONS {
		enc2302SwitchEvtPort,
		enc2302InputEvt,
		enc2302TempEvtSen,
		enc2302HygroEvtSen,
		enc2302InputEvtSen,
		enc2302AirPressureEvtSen,
		enc2302DewPtDiffEvtSen,
		enc2302StopChangeEvt,
		enc2302ExtInputEvt }
	STATUS  current
	DESCRIPTION ""
	-- 1.3.6.1.4.1.28507.70.2.1.2
	::= { enc2302Groups 2 }

-- Notification Types
--

events OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.3
	::= { gadsENC2302 3 }


enc2302HygroEvtSen NOTIFICATION-TYPE
	OBJECTS {
		enc2302SensorIndex,
		enc2302HygroSensor}
	STATUS  current
	DESCRIPTION
		"hygro limits exceeded"
	-- 1.3.6.1.4.1.28507.70.3.4
	::= { events 4 }


enc2302InputEvtSen NOTIFICATION-TYPE
	OBJECTS {
		enc2302SensorIndex,
		enc2302InputSensor}
	STATUS  current
	DESCRIPTION
		"change of logical input sensor state"
	-- 1.3.6.1.4.1.28507.70.3.5
	::= { events 5 }


enc2302AirPressureEvtSen NOTIFICATION-TYPE
	OBJECTS {
		enc2302SensorIndex,
		enc2302AirPressure}
	STATUS  current
	DESCRIPTION
		"Air Pressure limits exceeded

		"
	-- 1.3.6.1.4.1.28507.70.3.6
	::= { events 6 }


enc2302DewPtDiffEvtSen NOTIFICATION-TYPE
	OBJECTS {
		enc2302SensorIndex,
		enc2302DewPointDiff}
	STATUS  current
	DESCRIPTION
		"Dew Point Difference limits exceeded"
	-- 1.3.6.1.4.1.28507.70.3.7
	::= { events 7 }


enc2302TempEvtSen NOTIFICATION-TYPE
	OBJECTS {
		enc2302SensorIndex,
		enc2302TempSensor}
	STATUS  current
	DESCRIPTION
		"temperature limits exceeded"
	-- 1.3.6.1.4.1.28507.70.3.3
	::= { events 3 }


enc2302SwitchEvtPort NOTIFICATION-TYPE
	OBJECTS {
		enc2302PortIndex,
		enc2302PortName,
		enc2302PortState,
		enc2302PortSwitchCount}
	STATUS  current
	DESCRIPTION
		"Event is triggered when a port is switched"
	-- 1.3.6.1.4.1.28507.70.3.1
	::= { events 1 }


enc2302StopChangeEvt NOTIFICATION-TYPE
	OBJECTS {
		enc2302StopPressed}
	STATUS  current
	DESCRIPTION
		"Event is triggered when Stop condition
		changes"
	-- 1.3.6.1.4.1.28507.70.3.8
	::= { events 8 }

enc2302StopPressed OBJECT-TYPE
	SYNTAX  INTEGER {
			stopped(1),
			inactive(0) }
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"signals if Stop action active"
	-- 1.3.6.1.4.1.28507.70.1.5.12
	::= { enc2302IntSensors 12 }



enc2302ExtInputEvt NOTIFICATION-TYPE
	OBJECTS {
		enc2302ExtInputIndex,
		enc2302ExtInput,
		enc2302ExtInputToggleCount,
		enc2302ExtInputName,
		enc2302ExtInputPortNum,
		enc2302ExtInputBlockIndex}
	STATUS  current
	DESCRIPTION
		"Change of external sensor input."
	-- 1.3.6.1.4.1.28507.70.3.25
	::= { events 25 }


enc2302InputEvt NOTIFICATION-TYPE
	OBJECTS {
		enc2302InputIndex,
		enc2302Input,
		enc2302InputToggleCount}
	STATUS  current
	DESCRIPTION
		"Change of device input."
	-- 1.3.6.1.4.1.28507.70.3.2
	::= { events 2 }

enc2302DeviceInfo OBJECT IDENTIFIER 
	-- 1.3.6.1.4.1.28507.70.1.1.2
	::= { enc2302CommonConfig 2 }

enc2302ProdName OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"The Product Name of the device."
	-- 1.3.6.1.4.1.28507.70.1.1.2.1
	::= { enc2302DeviceInfo 1 }


enc2302FWVersion OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"Firmware Version of the device."
	-- 1.3.6.1.4.1.28507.70.1.1.2.2
	::= { enc2302DeviceInfo 2 }


enc2302HostName OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"The configured Host Name."
	-- 1.3.6.1.4.1.28507.70.1.1.2.3
	::= { enc2302DeviceInfo 3 }


enc2302PhysAddress OBJECT-TYPE
	SYNTAX  OCTET STRING
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"The MAC address of the device."
	-- 1.3.6.1.4.1.28507.70.1.1.2.4
	::= { enc2302DeviceInfo 4 }


enc2302SerialNumber OBJECT-TYPE
	SYNTAX  Unsigned32
	MAX-ACCESS read-only
	STATUS  current
	DESCRIPTION
		"The Serial Number of the device. Not available for all devices. Production start 2026."
	-- 1.3.6.1.4.1.28507.70.1.1.2.5
	::= { enc2302DeviceInfo 5 }


END