- v1.3.2 - 07.11.2023
- Features
- internal watchdog now additionally monitors MQTT operation
- Bugfixes
- fixed wrong MQTT JSON Device Data Summary when Sensor 7207 inserted
- corrected text in web interface showing countdown of coldstart batch sequence
- fixed eFuse handling when switching power source
- v1.3.1 - 22.08.2023
- Bugfixes
- 'Choose File' in SSL Cert upload now usable again
- fixed fallback to user/pass when SSH key denied
- v1.3.0 - 01.08.2023
- Features
- added session authentication with optional CSRF token in webserver
- updated SSL(TLS), SSH, jquery-UI libraries to newest versions
- support for new external sensors with additional inputs
- calibration data can be stored on external sensors
- warning when DHCP activated but gets no answer from DHCP server
- Bugfixes
- removed Ciphers with AES CBC from TLS and SSH
- removed SSH Ciphers with SHA1
- fixed possible buffer problem in webserver
- v1.2.1 - 23.02.2023
- Features
- extended MQTT telemetry with more electrical data
- removed 3DES TLS Ciphersuites (SWEET32)
- extended internal watchdog
- Bugfixes
- increased webserver stability when targeted by vulnerability scanners
- v1.2.0 - 12.08.2022
- Features
- new hardware platform components support
- Bugfixes
- DNS resolver stability improved
- RADIUS improved timing robustness
- SSH no more sensitive to time-critical spawning sessions
- ModbusTCP now shows correctly 0x8000 when sensor data not avail
- improved checking when uploading new certificates
- v1.1.1 - 11.03.2022
- Features
- better mail headers for improved SPAM scoring
- Bugfixes
- fixed html body when generating HTTP status codes
- better SMTP multiline recognition
- improved FW update over HTTPS slow connections
- v1.1.0 - 11.11.2021
- Features
- MQTT messaging support
- Extended sensor messaging trigger: time-interval and value-delta
- Support for serverside HTTP redirection to HTTPS
- v1.0.10 - 28.06.2021
- Bugfixes
- Sends SSL encrypted E-mails when HTTPs disabled
- Browser compatibility issues (IE)
- v1.0.9 - 27.05.2021
- Features
- config/status maintenance export.json
- Bugfixes
- restored iPhone App compatibility
- v1.0.7 - 12.04.2021
- Bugfixes
- E-Mails using CRLF as line separator to avoid 'bare linefeed rejection'
- v1.0.6 - 02.03.2021
- Features
- More sensor values selectable for front panel display
- Bugfixes
- Increased SMTP TCP timeout
- Small CLI syntax fixes
- Activated core stability monitor
- v1.0.3 - 01.12.2020
- Features
- New outlet icon set
- All On / All Off buttons, enabled via Fab-Default
- New Fab-Default: Initialization status (coldstart): remember last state
- Bugfixes
- CLI: time since last energy counter reset
- v1.0.1 - 26.10.2020
- Bugfixes
- Virtual outlet status of Bank-E reset save
- Batchmode option selection in Web-Interface
- Outlet config mapping error